Brand: Shenzhen Xinding Machinery
Product Name: Lab2000-2400 double station integrated single- sided glove box
Lab2000 glove box is a high-performance, high-quality closed-loop working system that automatically absorbs water and oxygen molecules and purifies the working environment. It provides 1ppm O2 and H2O inert atmosphere for your specific cleaning requirements. The system is an economical cycle purification system designed to meet the needs of customers for scientific research and development.
The Lab2000 system consists of a closed cabinet, a transition chamber, a rotary vane vacuum pump and a cycle purification system integrated with a microcontroller operating panel. The standard Lab2000 system is equipped with an inert gas purification system that is equipped with a purification column (automatic regenerative) to purify and maintain the atmosphere inside the glove box.
Box | ||
description | Material: stainless steel type 304 (1.4301) thickness 3 mm | |
Dimensions: 2400mm (L) x 750mm (W) x 900mm (H) | ||
volume | 1.6m3 | |
Front window | Panel: 8 mm thick safety tempered glass or 10 mm thick polycarbonate (optional) | |
Dimensions: 1123mm (L) x 839mm (H) | ||
Glove mouth | Hard aluminum alloy or polyacetal material (optional) | |
Caliber 220 mm, O-ring seal | ||
gloves | Material: butyl rubber | |
Thickness: 0.4 mm or 0.8mm (optional) | ||
filter | Outlet and inlet filters, filter <0.3μm | |
illumination | LED lighting is located at the top of the front window | |
Leak rate | The leak detection method is based on the oxygen-containing method and the pressure change method in ISO 10648-2:1994 / EJ/T 1096-1999 "Sealing Chamber Chamber - Part 2: Sealing Classification and Related Inspection Methods". Final acceptance testing was performed according to the criteria for primary sealability < 0.05 vol%/h. | |
GP20 gas purification system | ||
description | Automatic removal of H2O and O2 | |
Single purification column system, automatic regeneration (optional GP200 double purification column) | ||
Closed gas circulation line | ||
Use voltage | AC 230 V / 50-60 Hz, 10 A or AC 115 V / 50-60 Hz, 20 A (optional) | |
Working gas | Working gas: N2, Ar, He (purity ≥99.999%) | |
Regeneration gas: H2 accounts for 5%-10%, and the rest is working gas (purity ≥99.999%) | ||
Vacuum pump | Specifications: rotary vane vacuum pump, with oil mist filter, with gas town control | |
Flow rate: 12 m3/h (7 cfm), double substrate, vacuum < 2 x 10-3 mbar or dry pump (optional) | ||
Circulating unit | Oil-free high-speed fan | |
Air volume: 80 m3/h | ||
valve | KF40 high vacuum valve | |
Leak rate | The leak detection method is based on the oxygen-containing method and the pressure change method in ISO 10648-2:1994 / EJ/T 1096-1999 "Sealing Chamber Chamber - Part 2: Sealing Classification and Related Inspection Methods". Final acceptance testing was performed according to the criteria for Class 1 sealing < 0.05 vol%/h. | |
Control cabinet size | 600mm(L) x 800mm(D) x 870mm(H) | |
Transition cabin | ||
Large transition cabin | material | Stainless steel type 304 (1.4301), thickness 3 mm |
size | Φ360mmx600mm(L) or φ390mmx600mm(L) (optional) | |
Vacuum degree | < 1 x 10-2 mbar | |
Small transition cabin | material | Stainless steel type 304 (1.4301), thickness 2 mm |
size | Φ150mm x 330mm(L) | |
Vacuum degree | < 1 x 10-2 mbar | |
Cleaning system | ||
description | Set the appropriate time and pressure, the system can automatically replace the gas. | |
Analyzer | ||
Oxygen analyzer | size | 205 mm (L) x 80 mm (W) x 60 mm (H) |
Measuring range | 0-1000 ppm | |
Other oxygen analyzer | GE oxy.IQTM Oxygen Transmitter | |
Moisture analyzer | size | 205 mm (L) x 80 mm (W) x 60 mm (H) |
Measuring range | 0-500 ppm | |
Other water analyzer | GE VeriDriTM Dew-Point Transmitter | |
Solvent purification system | ||
description | Material: Stainless steel 1.4301 (SUS type 304), thickness 3 mm | |
Internal dimensions: 220mm (Φ) x 450mm (H) | ||
High quality activated carbon | ||
Optional equipment | ||
refrigerator | Independent control system, integrated in the side panel of the cabinet, temperature -35 ° C, volume 18L or 32L | |
Main body 304 stainless steel sheet, 5 layers of variable compartment | ||
R404 environmentally friendly refrigerant, imported | ||
Heating cabin | Large transition cabin with heating system, temperature is 200 °C, temperature control ± 1 °C | |
other instructions | ||
certified product | ISO9001 certification, CE certification, UL certification | |
Warranty | One year warranty period, lifetime maintenance | |
Application considerations | For details, please refer to the instructions for dangers, warnings, cautions, etc. | |
Package size (W × D × H) | ||
weight |
Lab2000 glove box is a high-performance, high-quality closed-loop working system that automatically absorbs water and oxygen molecules and purifies the working environment. It provides 1ppm O2 and H2O inert atmosphere for your specific cleaning requirements. The system is an economical cycle purification system designed to meet the needs of customers for scientific research and development.
The Lab2000 system consists of a closed cabinet, a transition chamber, a rotary vane vacuum pump and a cycle purification system integrated with a microcontroller operating panel. The standard Lab2000 system is equipped with an inert gas purification system that is equipped with a purification column (automatic regenerative) to purify and maintain the atmosphere inside the glove box.
Box | ||
description | Material: stainless steel type 304 (1.4301) thickness 3 mm | |
Dimensions: 2400mm (L) x 750mm (W) x 900mm (H) | ||
volume | 1.6m3 | |
Front window | Panel: 8 mm thick safety tempered glass or 10 mm thick polycarbonate (optional) | |
Dimensions: 1123mm (L) x 839mm (H) | ||
Glove mouth | Hard aluminum alloy or polyacetal material (optional) | |
Caliber 220 mm, O-ring seal | ||
gloves | Material: butyl rubber | |
Thickness: 0.4 mm or 0.8mm (optional) | ||
filter | Outlet and inlet filters, filter <0.3μm | |
illumination | LED lighting is located at the top of the front window | |
Leak rate | The leak detection method is based on the oxygen-containing method and the pressure change method in ISO 10648-2:1994 / EJ/T 1096-1999 "Sealing Chamber Chamber - Part 2: Sealing Classification and Related Inspection Methods". Final acceptance testing was performed according to the criteria for primary sealability < 0.05 vol%/h. | |
GP20 gas purification system | ||
description | Automatic removal of H2O and O2 | |
Single purification column system, automatic regeneration (optional GP200 double purification column) | ||
Closed gas circulation line | ||
Use voltage | AC 230 V / 50-60 Hz, 10 A or AC 115 V / 50-60 Hz, 20 A (optional) | |
Working gas | Working gas: N2, Ar, He (purity ≥99.999%) | |
Regeneration gas: H2 accounts for 5%-10%, and the rest is working gas (purity ≥99.999%) | ||
Vacuum pump | Specifications: rotary vane vacuum pump, with oil mist filter, with gas town control | |
Flow rate: 12 m3/h (7 cfm), double substrate, vacuum < 2 x 10-3 mbar or dry pump (optional) | ||
Circulating unit | Oil-free high-speed fan | |
Air volume: 80 m3/h | ||
valve | KF40 high vacuum valve | |
Leak rate | The leak detection method is based on the oxygen-containing method and the pressure change method in ISO 10648-2:1994 / EJ/T 1096-1999 "Sealing Chamber Chamber - Part 2: Sealing Classification and Related Inspection Methods". Final acceptance testing was performed according to the criteria for Class 1 sealing < 0.05 vol%/h. | |
Control cabinet size | 600mm(L) x 800mm(D) x 870mm(H) | |
Transition cabin | ||
Large transition cabin | material | Stainless steel type 304 (1.4301), thickness 3 mm |
size | Φ360mmx600mm(L) or φ390mmx600mm(L) (optional) | |
Vacuum degree | < 1 x 10-2 mbar | |
Small transition cabin | material | Stainless steel type 304 (1.4301), thickness 2 mm |
size | Φ150mm x 330mm(L) | |
Vacuum degree | < 1 x 10-2 mbar | |
Cleaning system | ||
description | Set the appropriate time and pressure, the system can automatically replace the gas. | |
Analyzer | ||
Oxygen analyzer | size | 205 mm (L) x 80 mm (W) x 60 mm (H) |
Measuring range | 0-1000 ppm | |
Other oxygen analyzer | GE oxy.IQTM Oxygen Transmitter | |
Moisture analyzer | size | 205 mm (L) x 80 mm (W) x 60 mm (H) |
Measuring range | 0-500 ppm | |
Other water analyzer | GE VeriDriTM Dew-Point Transmitter | |
Solvent purification system | ||
description | Material: Stainless steel 1.4301 (SUS type 304), thickness 3 mm | |
Internal dimensions: 220mm (Φ) x 450mm (H) | ||
High quality activated carbon | ||
Optional equipment | ||
refrigerator | Independent control system, integrated in the side panel of the cabinet, temperature -35 ° C, volume 18L or 32L | |
Main body 304 stainless steel sheet, 5 layers of variable compartment | ||
R404 environmentally friendly refrigerant, imported | ||
Heating cabin | Large transition cabin with heating system, temperature is 200 °C, temperature control ± 1 °C | |
other instructions | ||
certified product | ISO9001 certification, CE certification, UL certification | |
Warranty | One year warranty period, lifetime maintenance | |
Application considerations | For details, please refer to the instructions for dangers, warnings, cautions, etc. | |
Package size (W × D × H) | ||
weight |
0755-27806324 Email:17307550303@139.com
Mr Guo:17307550303 For the record number: guangdong ICP for 19078327
Address: shenzhen baoan district xinqiao street zhuang village
new two community professional Fang Yongfa technology park five layer building workshop A
Mobile station